Re: Running service from house to garage

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Re: Running service from house to garage RBM 03-18-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by RBM on March 18, 2007, 5:25 pm


If it's a decent, fairly straight and clean run, you could pull 3 #8 and
1#10 for the ground,THWN conductors, use a six circuit panel two ground rods
connected with #8 and a 40 amp breaker in the main panel



> The conduit is 3/4"
>
>