On 16 May 2006 11:30:22 -0700, deanwil@msn.com wrote:
>Voltage dropout is a type of conducted susceptibility noise. The
>length of the dropout determines whether it is just a transient, or a
>true brownout.
>
>Avionics systems are supposed to be able to handle short term dropouts
>associated with bus switching, etc. Maybe this one is poorly
>designed...
>
>Dean
the guy needs to put a fast sampling volt meter on it and redo the
sequence.
the chopper outages were only identified when the data from the meter
was uploaded to a pc and looked through with an excel spreadsheet.
you never would have picked it while looking at the meter display.
Stealth Pilot
|
|